Live 24/7
J News Network — The Number One Source for All Public Information
Fallout Files FEATURED News Ohio

A hole in the tunnel: Regulators found Haverhill Coke’s quench towers falling apart — and Ohio let it run with its scrubber shut down

A November 6 violation notice documents smoke pouring from a hole in the Haverhill Coke battery tunnel, quench towers with plugged sprays, missing diverters and baffles left broken for 50 days — two months after Ohio EPA authorized the plant to run its battery with its desulfurization unit shut down.

Advertisement
Page 1 of the Notice of Violation to Haverhill Coke Company, November 6, 2026
Page 1 of the Notice of Violation, November 6, 2026. (Portsmouth Local Air Agency)

Read the full Notice of Violation (PDF, 6 pages)

Running with the scrubber off

On August 21, 2026, Haverhill Coke wrote to the regulators asking permission to keep operating its coke oven battery — emissions unit P902 — while the Flue Gas Desulfurization Unit, the equipment that controls that battery’s emissions, was shut down for scheduled maintenance.

Advertisement
Advertisement
CapCut

On September 11, 2026, Ohio EPA Director John Logue granted it: “I hereby authorize HCC to operate the coke oven battery while the FGD is shut down,” on the conditions in the company’s own letter. The authorization can be revoked at any time, and it does not shield the company from liability — but it contains no dates, no duration and no emissions figures. Those are in the company’s August 21 letter, which is not part of the public document.

Ohio EPA Director John Logue's September 11, 2026 authorization letter to Haverhill Coke Company
Ohio EPA’s September 11, 2026 authorization — the battery may run while its desulfurization unit is down. (Ohio EPA)

Read the full authorization letter (PDF, 2 pages)

Advertisement
Southwest Airlines Rapid Rewards

What happens now

The violation notice is not a fine — no penalty is assessed in it. What it does is start clocks: root-cause and repair documentation, detailed compliance plans with milestone dates, and five years of maintenance records are all due to the Portsmouth Local Air Agency within 30 days of the company’s receipt of the November 6 letter. The notice closes with the warning that failure to comply “may result in an administrative or civil penalty” — and that answering the letter does not waive Ohio EPA’s authority to seek one.

Advertisement

At the same time, the plant’s next decade is being papered: Ohio EPA issued the draft renewal of Haverhill Coke’s Title V air permit for public comment on November 19, 2026, and finalized a permit-to-install modification on November 18. The comment window on the draft renewal is the public’s one formal seat at that table.

Haverhill Coke sits in Franklin Furnace, a few miles up Gallia Pike from the ALTIVIA chemical plant at Haverhill — where, as JNN reported today, the 2026 groundwater monitoring found five industrial solvents above federal drinking-water limits under the plant. Two Haverhills. One with a plume underneath it; one with a hole in the tunnel and a state permission slip to run with its scrubber off.

Page 2 of the Notice of Violation: the quench-water exceedances and the opacity violations from the hole near Ovens 2 and 3
Page 2 of the Notice of Violation — the quench-water exceedances, and the opacity violations from the hole in the tunnel near Ovens 2 and 3. (Portsmouth Local Air Agency / Ohio EPA public record)

The quench towers

The rest of the notice reads like an inventory of a plant coming apart. Inspectors who visited on March 5, April 8 and September 29, 2026 — and the company’s own monthly inspection records — document, for the two quench towers that douse the finished coke:

  • More than 20 of 39 baffle sprays plugged.
  • The internal water diverter missing in pieces — the inspectors’ notes read “missing,” “all of west side,” “¾ of it’s missing,” “over half missing,” “2/3 missing,” “all of it needs replaced.”
  • Holes and damage across both quench hoods — “all of hood,” “needs replaced,” “missing pieces,” “hole in south side.”
  • Up to 45 missing side boards and 135 damaged ones.
  • Baffles with “significant blockage, scaling, clogging, corrosion and warping” — the inspection form the company uses doesn’t even have a box for blockage, which federal rules require it to check monthly.
Page 5 of the Notice of Violation with the inspectors' photographs of the P002 quench tower baffles, April 8 and September 29, 2026
The agency’s own photographs of the inside of the P002 quench tower, April 8 and September 29, 2026 — printed in the Notice of Violation. (Portsmouth Local Air Agency)

One repair tells the pattern. A work order for quench tower 1’s baffles and top spray — not working — was opened September 11, 2025. The repair was not started until October 31, 2025, fifty days later, against a federal rule that gives the company thirty. The breakdown was never reported in the company’s quarterly deviation report or its semi-annual federal compliance report, either.

The paperwork is in the same shape as the towers. Monthly inspection records are missing from the plant’s hard-copy files for stretches of 2024 through 2026. Work orders are answered “see comment” with no comments attached. The official inspection record is kept on the back of another form. And the plant’s written Operation and Maintenance Plan — the document that is supposed to govern all of it — was last revised in April 2021.

The water

One finding the agency considers closed: for three weeks in early 2026 — January 26, February 2 and February 9 — the water used to quench the coke ran over its dissolved-solids limit, at 1,208, 1,171 and 1,143 milligrams per liter against a limit of 1,100. The company attributed it to a frozen river water line and installed a potable water backup line in February; the agency counts those violations resolved.

Page 1 of the Notice of Violation to Haverhill Coke Company, November 6, 2026
Page 1 of the Notice of Violation, November 6, 2026. (Portsmouth Local Air Agency)

Read the full Notice of Violation (PDF, 6 pages)

Running with the scrubber off

On August 21, 2026, Haverhill Coke wrote to the regulators asking permission to keep operating its coke oven battery — emissions unit P902 — while the Flue Gas Desulfurization Unit, the equipment that controls that battery’s emissions, was shut down for scheduled maintenance.

On September 11, 2026, Ohio EPA Director John Logue granted it: “I hereby authorize HCC to operate the coke oven battery while the FGD is shut down,” on the conditions in the company’s own letter. The authorization can be revoked at any time, and it does not shield the company from liability — but it contains no dates, no duration and no emissions figures. Those are in the company’s August 21 letter, which is not part of the public document.

Ohio EPA Director John Logue's September 11, 2026 authorization letter to Haverhill Coke Company
Ohio EPA’s September 11, 2026 authorization — the battery may run while its desulfurization unit is down. (Ohio EPA)

Read the full authorization letter (PDF, 2 pages)

What happens now

The violation notice is not a fine — no penalty is assessed in it. What it does is start clocks: root-cause and repair documentation, detailed compliance plans with milestone dates, and five years of maintenance records are all due to the Portsmouth Local Air Agency within 30 days of the company’s receipt of the November 6 letter. The notice closes with the warning that failure to comply “may result in an administrative or civil penalty” — and that answering the letter does not waive Ohio EPA’s authority to seek one.

At the same time, the plant’s next decade is being papered: Ohio EPA issued the draft renewal of Haverhill Coke’s Title V air permit for public comment on November 19, 2026, and finalized a permit-to-install modification on November 18. The comment window on the draft renewal is the public’s one formal seat at that table.

Haverhill Coke sits in Franklin Furnace, a few miles up Gallia Pike from the ALTIVIA chemical plant at Haverhill — where, as JNN reported today, the 2026 groundwater monitoring found five industrial solvents above federal drinking-water limits under the plant. Two Haverhills. One with a plume underneath it; one with a hole in the tunnel and a state permission slip to run with its scrubber off.

The hole was in the tunnel that runs the length of the coke battery, near Ovens 2 and 3. For three days spread across the fall of 2025 — October 27, November 4 and December 9 — smoke poured out of it at levels regulators measured at 22.1%, 22.1% and 14.2% opacity, at a plant whose air permit allows no visible emissions from that tunnel at all.

That is one of five findings in a Notice of Violation the Portsmouth Local Air Agency sent Haverhill Coke Company on November 6, 2026 — a six-page catalogue of decay at the coke plant on Gallia Pike in Franklin Furnace, in Scioto County. And two months before the violation notice landed, Ohio EPA’s director had signed a letter letting the same plant keep running its coke battery with the equipment that scrubs its sulfur emissions shut down.

The hole

The opacity violations were reported by Haverhill Coke itself, in its Fourth Quarter 2025 deviation report: smoke escaping the Battery A common tunnel, traced to a hole near Ovens 2 and 3. The permit term is absolute — “no visible particulate emissions shall be permitted from the common battery tunnel or its associate piping.”

The agency’s demand: within 30 days of receiving the letter, the company must hand over a detailed summary of what caused the hole, what was done to repair it, and the procedures in place for running the ovens under negative pressure — the condition that keeps emissions inside the tunnel instead of pushing them out through holes in it.

Page 2 of the Notice of Violation: the quench-water exceedances and the opacity violations from the hole near Ovens 2 and 3
Page 2 of the Notice of Violation — the quench-water exceedances, and the opacity violations from the hole in the tunnel near Ovens 2 and 3. (Portsmouth Local Air Agency / Ohio EPA public record)

The quench towers

The rest of the notice reads like an inventory of a plant coming apart. Inspectors who visited on March 5, April 8 and September 29, 2026 — and the company’s own monthly inspection records — document, for the two quench towers that douse the finished coke:

  • More than 20 of 39 baffle sprays plugged.
  • The internal water diverter missing in pieces — the inspectors’ notes read “missing,” “all of west side,” “¾ of it’s missing,” “over half missing,” “2/3 missing,” “all of it needs replaced.”
  • Holes and damage across both quench hoods — “all of hood,” “needs replaced,” “missing pieces,” “hole in south side.”
  • Up to 45 missing side boards and 135 damaged ones.
  • Baffles with “significant blockage, scaling, clogging, corrosion and warping” — the inspection form the company uses doesn’t even have a box for blockage, which federal rules require it to check monthly.
Page 5 of the Notice of Violation with the inspectors' photographs of the P002 quench tower baffles, April 8 and September 29, 2026
The agency’s own photographs of the inside of the P002 quench tower, April 8 and September 29, 2026 — printed in the Notice of Violation. (Portsmouth Local Air Agency)

One repair tells the pattern. A work order for quench tower 1’s baffles and top spray — not working — was opened September 11, 2025. The repair was not started until October 31, 2025, fifty days later, against a federal rule that gives the company thirty. The breakdown was never reported in the company’s quarterly deviation report or its semi-annual federal compliance report, either.

The paperwork is in the same shape as the towers. Monthly inspection records are missing from the plant’s hard-copy files for stretches of 2024 through 2026. Work orders are answered “see comment” with no comments attached. The official inspection record is kept on the back of another form. And the plant’s written Operation and Maintenance Plan — the document that is supposed to govern all of it — was last revised in April 2021.

The water

One finding the agency considers closed: for three weeks in early 2026 — January 26, February 2 and February 9 — the water used to quench the coke ran over its dissolved-solids limit, at 1,208, 1,171 and 1,143 milligrams per liter against a limit of 1,100. The company attributed it to a frozen river water line and installed a potable water backup line in February; the agency counts those violations resolved.

Page 1 of the Notice of Violation to Haverhill Coke Company, November 6, 2026
Page 1 of the Notice of Violation, November 6, 2026. (Portsmouth Local Air Agency)

Read the full Notice of Violation (PDF, 6 pages)

Running with the scrubber off

On August 21, 2026, Haverhill Coke wrote to the regulators asking permission to keep operating its coke oven battery — emissions unit P902 — while the Flue Gas Desulfurization Unit, the equipment that controls that battery’s emissions, was shut down for scheduled maintenance.

On September 11, 2026, Ohio EPA Director John Logue granted it: “I hereby authorize HCC to operate the coke oven battery while the FGD is shut down,” on the conditions in the company’s own letter. The authorization can be revoked at any time, and it does not shield the company from liability — but it contains no dates, no duration and no emissions figures. Those are in the company’s August 21 letter, which is not part of the public document.

Ohio EPA Director John Logue's September 11, 2026 authorization letter to Haverhill Coke Company
Ohio EPA’s September 11, 2026 authorization — the battery may run while its desulfurization unit is down. (Ohio EPA)

Read the full authorization letter (PDF, 2 pages)

What happens now

The violation notice is not a fine — no penalty is assessed in it. What it does is start clocks: root-cause and repair documentation, detailed compliance plans with milestone dates, and five years of maintenance records are all due to the Portsmouth Local Air Agency within 30 days of the company’s receipt of the November 6 letter. The notice closes with the warning that failure to comply “may result in an administrative or civil penalty” — and that answering the letter does not waive Ohio EPA’s authority to seek one.

At the same time, the plant’s next decade is being papered: Ohio EPA issued the draft renewal of Haverhill Coke’s Title V air permit for public comment on November 19, 2026, and finalized a permit-to-install modification on November 18. The comment window on the draft renewal is the public’s one formal seat at that table.

Haverhill Coke sits in Franklin Furnace, a few miles up Gallia Pike from the ALTIVIA chemical plant at Haverhill — where, as JNN reported today, the 2026 groundwater monitoring found five industrial solvents above federal drinking-water limits under the plant. Two Haverhills. One with a plume underneath it; one with a hole in the tunnel and a state permission slip to run with its scrubber off.

The hole was in the tunnel that runs the length of the coke battery, near Ovens 2 and 3. For three days spread across the fall of 2025 — October 27, November 4 and December 9 — smoke poured out of it at levels regulators measured at 22.1%, 22.1% and 14.2% opacity, at a plant whose air permit allows no visible emissions from that tunnel at all.

That is one of five findings in a Notice of Violation the Portsmouth Local Air Agency sent Haverhill Coke Company on November 6, 2026 — a six-page catalogue of decay at the coke plant on Gallia Pike in Franklin Furnace, in Scioto County. And two months before the violation notice landed, Ohio EPA’s director had signed a letter letting the same plant keep running its coke battery with the equipment that scrubs its sulfur emissions shut down.

The hole

The opacity violations were reported by Haverhill Coke itself, in its Fourth Quarter 2025 deviation report: smoke escaping the Battery A common tunnel, traced to a hole near Ovens 2 and 3. The permit term is absolute — “no visible particulate emissions shall be permitted from the common battery tunnel or its associate piping.”

The agency’s demand: within 30 days of receiving the letter, the company must hand over a detailed summary of what caused the hole, what was done to repair it, and the procedures in place for running the ovens under negative pressure — the condition that keeps emissions inside the tunnel instead of pushing them out through holes in it.

Page 2 of the Notice of Violation: the quench-water exceedances and the opacity violations from the hole near Ovens 2 and 3
Page 2 of the Notice of Violation — the quench-water exceedances, and the opacity violations from the hole in the tunnel near Ovens 2 and 3. (Portsmouth Local Air Agency / Ohio EPA public record)

The quench towers

The rest of the notice reads like an inventory of a plant coming apart. Inspectors who visited on March 5, April 8 and September 29, 2026 — and the company’s own monthly inspection records — document, for the two quench towers that douse the finished coke:

  • More than 20 of 39 baffle sprays plugged.
  • The internal water diverter missing in pieces — the inspectors’ notes read “missing,” “all of west side,” “¾ of it’s missing,” “over half missing,” “2/3 missing,” “all of it needs replaced.”
  • Holes and damage across both quench hoods — “all of hood,” “needs replaced,” “missing pieces,” “hole in south side.”
  • Up to 45 missing side boards and 135 damaged ones.
  • Baffles with “significant blockage, scaling, clogging, corrosion and warping” — the inspection form the company uses doesn’t even have a box for blockage, which federal rules require it to check monthly.
Page 5 of the Notice of Violation with the inspectors' photographs of the P002 quench tower baffles, April 8 and September 29, 2026
The agency’s own photographs of the inside of the P002 quench tower, April 8 and September 29, 2026 — printed in the Notice of Violation. (Portsmouth Local Air Agency)

One repair tells the pattern. A work order for quench tower 1’s baffles and top spray — not working — was opened September 11, 2025. The repair was not started until October 31, 2025, fifty days later, against a federal rule that gives the company thirty. The breakdown was never reported in the company’s quarterly deviation report or its semi-annual federal compliance report, either.

The paperwork is in the same shape as the towers. Monthly inspection records are missing from the plant’s hard-copy files for stretches of 2024 through 2026. Work orders are answered “see comment” with no comments attached. The official inspection record is kept on the back of another form. And the plant’s written Operation and Maintenance Plan — the document that is supposed to govern all of it — was last revised in April 2021.

The water

One finding the agency considers closed: for three weeks in early 2026 — January 26, February 2 and February 9 — the water used to quench the coke ran over its dissolved-solids limit, at 1,208, 1,171 and 1,143 milligrams per liter against a limit of 1,100. The company attributed it to a frozen river water line and installed a potable water backup line in February; the agency counts those violations resolved.

Page 1 of the Notice of Violation to Haverhill Coke Company, November 6, 2026
Page 1 of the Notice of Violation, November 6, 2026. (Portsmouth Local Air Agency)

Read the full Notice of Violation (PDF, 6 pages)

Running with the scrubber off

On August 21, 2026, Haverhill Coke wrote to the regulators asking permission to keep operating its coke oven battery — emissions unit P902 — while the Flue Gas Desulfurization Unit, the equipment that controls that battery’s emissions, was shut down for scheduled maintenance.

On September 11, 2026, Ohio EPA Director John Logue granted it: “I hereby authorize HCC to operate the coke oven battery while the FGD is shut down,” on the conditions in the company’s own letter. The authorization can be revoked at any time, and it does not shield the company from liability — but it contains no dates, no duration and no emissions figures. Those are in the company’s August 21 letter, which is not part of the public document.

Ohio EPA Director John Logue's September 11, 2026 authorization letter to Haverhill Coke Company
Ohio EPA’s September 11, 2026 authorization — the battery may run while its desulfurization unit is down. (Ohio EPA)

Read the full authorization letter (PDF, 2 pages)

What happens now

The violation notice is not a fine — no penalty is assessed in it. What it does is start clocks: root-cause and repair documentation, detailed compliance plans with milestone dates, and five years of maintenance records are all due to the Portsmouth Local Air Agency within 30 days of the company’s receipt of the November 6 letter. The notice closes with the warning that failure to comply “may result in an administrative or civil penalty” — and that answering the letter does not waive Ohio EPA’s authority to seek one.

At the same time, the plant’s next decade is being papered: Ohio EPA issued the draft renewal of Haverhill Coke’s Title V air permit for public comment on November 19, 2026, and finalized a permit-to-install modification on November 18. The comment window on the draft renewal is the public’s one formal seat at that table.

Haverhill Coke sits in Franklin Furnace, a few miles up Gallia Pike from the ALTIVIA chemical plant at Haverhill — where, as JNN reported today, the 2026 groundwater monitoring found five industrial solvents above federal drinking-water limits under the plant. Two Haverhills. One with a plume underneath it; one with a hole in the tunnel and a state permission slip to run with its scrubber off.

Advertisement
Whatnot

Leave a Reply

Verified Website

See Report

AdvertisementShopify